Analog Instrument

Square shape Indicator
 For model RD, RP series

  • ・Lineup with 4 types
  • ・Easy-to-Read with clear indicator
  • ・Variety of scale and unit availbale
  • ・Easy installation
  • ・Bright scale face with wide surface range

Operation manual

Main specification

Model T□RD-43 T□RD-21 T□RP-25 TSRP-80AA
Symbol of operating principles Each '□' symbol is filled with operating principle below.
'M' : Moving Coil type
'C' : Rectifier type
'A' : RMS effective value type
'S' : Moving Iron type
'e.g. TMRD-43 is a 43mm squre meter with moving coil.
Standard Specification Dimension 43 x 43 mm 60 x 60 mm 80 x 80 mm 82 x 82 mm
Weight
(1 mA DC rated)
0.04kg 0.07kg 0.12kg 0.1kg (5A)
Operating Principles
DC : Moving Coil type
AC : Rectifier type
  RMS effective value type
(for Ammeter more than 1A)
AC : Moving Iron type
Accuracy Class Class 2.5
Length of Scale 30 mm 49 mm 62 mm 70 mm
Shape of pointer Black bar
Color of indicator panel White
Color of cover Transparent Black
Test Voltage Terminal/Outer case More than AC 2210 V 5sec.
Operating temperature 0 to 40 ℃
Operating humidity 30 to 90 %RH (No Condensing) 40 to 75 %RH
(No Condensing)
Standard Rated Input DC Ammeter
(Moving coil)
1 mA,
10 mA to 1 A
100 μA, 500 μA, 1 mA -
10 mA to 10 A 10 mA to 20 A
DC Voltmeter
(Moving coil)
1 to 150 V 1 to 300 V -
Receiving meter
(Moving coil)
4 to 20 mA 4 to 20 mA
1 to 5 V (4 kΩ)
1 to 5 V (1 MΩ, with Converter 7331)
-
AC Ammeter Rectifier type - 1 mA to 10 mA 1 mA to 300 mA -
RMS effective value type 1 A to 30 A (with external Coverter 7311) -
Moving Iron type - 1 to 30 A
AC Voltmeter Rectifier type 10 V to 150 V 10 to 300 V -
Moving Iron type -

◎Twice or three times extended scale can be manufactured if AC Ammeter of RMS type and moving coil type of analog meter.
◎When the rated value is exceeded in DC Ammeter, connect the shunt and analog meter with 60 mV rated value.
◎When the rated value is exceeded in DC voltmeter, connect the multiplier and analog meter with 1 mA rated voltage.
◎When the rated value is exceeded in AC Ammeter, connect the current transformer (CT) with analog meter with 5 A rated current.
◎When the rated value is exceeded in AC voltmeter, connect voltage transformer (VT) and analog meter with 100 V rated voltage.

Customers are requested to provide the following information during order.

  1. 1. Model
  2. 2. Rated input value
  3. 3. Scale and Unit
  4. ※Receiving meter of DC 1 to 5 V (1 MΩ)needs power supply.