Analog Instrument
Meter Relay
- ・Lineup with 3 edgewise types of Meter Relay.
- ・Suitable for display and control of tank capacity and level.
- ・Bright panel surface and easy to read values.
Specification / Model | NRE-65AH NRE-65AHL |
NRE-100AH NRE-100AHL |
NRE-152H NRE-152HL |
|||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||
H : High value setting, relay contact output HL : High and Low value setting, relay contact output | ||||||||||||||||||
Dimension (mm) |
22(W)×65(H) | ● | - | - | ||||||||||||||
30(W)×100(H) | - | ● | - | |||||||||||||||
50.7(W)×152.3(H) | - | - | ● | |||||||||||||||
Weight (1 mA d.c. rated) |
approx. 150 g | approx. 320 g | approx. 1,300 g | |||||||||||||||
TYPE | Edgewise | |||||||||||||||||
Input (*1) | DC Current | (Moving coil) | 10 μA - 1A | 100 μA, 1mA, 10 mA - 1 A |
1 mA | |||||||||||||
DC Voltage | (Moving coil) | 10 mV - 300 V | 1 V - 300 V | |||||||||||||||
Process | (Moving coil) | 4 - 20mA, 1 - 5 V(500kΩ) |
4 - 20mA, 1 - 5 V(4kΩ), 1 - 5 V (w / 1MΩ / 7331) |
4 - 20mA, 1 - 5 V(4kΩ), 1 - 5 V(1MΩ) |
||||||||||||||
AC Current | (average) | 1 - 300mA (w / 7331) |
1 - 300mA | 1mA | ||||||||||||||
(r.m.s., 1A or more) | 1 - 30 A ( w / 7311) |
1 - 5 A (CT incorporated), 10 -30 A (w / 7311) |
||||||||||||||||
AC Voltage | (average) | 10 - 300V | ||||||||||||||||
Display | Accuracy | Class 1.5 | - | ● | ● | |||||||||||||
Class 2.5 | ● | - | - | |||||||||||||||
Scale length | 44 mm | 82 mm | 100 mm | |||||||||||||||
Scale divisions | 20 - 37.5 | ● | - | ● | ||||||||||||||
30 - 50 | - | ● | - | |||||||||||||||
Scale Pointer | Needle type, red | Flat Type, red | Large type, red | |||||||||||||||
Scale plate color | White | |||||||||||||||||
Cover color | Black | - | - | ● | ||||||||||||||
7.5BG4/1.5 | - | - | ○ | |||||||||||||||
Transparence (non-electrification resin) |
● | ● | - | |||||||||||||||
Output | Operation type | Optical | - | ● | ● | |||||||||||||
Electrical | ● | - | - | |||||||||||||||
Output | Hold (relay) | |||||||||||||||||
Pointer | Knife shape H(High) : Red, L(Low) : Green | |||||||||||||||||
Setting range | 0 - 100% of scale for H and L | |||||||||||||||||
Setting | HL (High / Low ) or H (High) | |||||||||||||||||
minimum setting range(*2) | Less than 3 % | |||||||||||||||||
Pick up accuracy(*2) | Less than 2.5 % | Less than 1.0 % | ||||||||||||||||
Deadband (*2) | Less than 0.5 % | |||||||||||||||||
Temp. coefficient (*2) (pick up value change at rated voltage ± 10 %) |
Less than 0.5 % | Less than 0.3 % | ||||||||||||||||
Power regulation (*2) (pick up value change at rated voltage ± 10 %) |
Less than 0.5 % | Less than 0.3 % | ||||||||||||||||
Output contact | 1 transfer for H and L (NRE-152: N/O or N/C selectable) |
|||||||||||||||||
Contact rate (load resistance) | 250 V, 2 A a.c. 220 V, 2 A d.c. |
230 V, 3 A a.c. 30 V, 3 A d.c. |
230V, 2.5A a.c. 30V, 2.5A d.c. |
|||||||||||||||
100/110,200/220V AC (w / transformer **) | ●(*3) | ● | ● (*4) | |||||||||||||||
24V DC | ○ | ○ | ○ | |||||||||||||||
Power consumption | approx. 2VA | 2.5VA or less | 3VA or less | |||||||||||||||
Operating temperature | 0 – 50°C | |||||||||||||||||
Operating humidity | 30 - 90%RH (no condensation) |
- *1
- When the rated input exceeds the specific standard, accessory is included with product.
- *2
- It is the value against the scale length.
- *3
- The power supply terminal is not insulated from the measurement input terminal. If the transformer is not used, insulate the measurement input from the power supply.
- *4
- The power source and the input are not insulated in the receiver (1 to 5V, 1MΩ). Insulate the measurement input and power supply when needed.
●:Standard, ○:Option
Customers are requested to provide the following information during order.
- 1. Model ( HL or H )
- 2. Rated value (Input signal with AC or DC type)
- 3. Scale and Unit
- 4. Position (Horizontal or Vertical )
- 5. Power supply
・AC 100/110 V ± 10% or AC 200/220 V ± 10% ( 50/60 Hz )
・DC 24V ± 10%