Edgewise shape Indicator
For model TME, TCE, TAE series
- ・Lineup with 6 types from small to large
- ・Easy-to-Read with clear indicator
- ・Variety of scale and unit available
- ・Easy installation
- ・Two or more units can be connected (T□E-100A)
- ・Tag plates are attached to the top of display to display information such as measuring place, name and tag No.(T□E-120, T□E-152)
Main specification
Model | T□E-45A | T□E-60C | T□E-80B | T□E-100A | T□E-120 | T□E-152 | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Symbol of operating principles | Each '□' symbol is filled with operating principle below.
| |||||||||||||
Standard Specification | Dimension | 44.5 x 13 mm | 60 x 22 mm | 80 x 16 mm | 100 x 30 mm | 120 x 46 mm | 152.3 x 50.7 mm | |||||||
Weight (1 mA DC rated) |
0.04kg | 0.14kg | 0.175kg | 0.23kg | 0.55kg | 1.1kg | ||||||||
Operating Principles |
|
|||||||||||||
Accuracy Class | Class 2.5 | Class 1.5 | ||||||||||||
Length of Scale | 34.5 mm | 46 mm | 64 mm | 82 mm | 80 mm | 100 mm | ||||||||
Shape of pointer | Red bar | Red, flat | Red, larger bar | |||||||||||
Color of indicator panel | White | |||||||||||||
Color of cover | Transparent (anti-static resin) | Black | ||||||||||||
Test Voltage | Terminal/Outer case More than AC 2210 V 5sec. | |||||||||||||
Operating temperature | 0 to 40 ℃ | |||||||||||||
Operating humidity | 30 to 90 %RH (No Condensing) | |||||||||||||
Standard Rated Input | DC Ammeter (Moving coil) |
50 μA, 100 μA, 500 μA, 1 mA, 10 mA |
50 μA, 100 μA, 1 mA, 10 mA to 1 A |
100 μA, 1 mA, 10 mA to 1 A |
1 mA, 10 mA to 20 A |
1 mA | ||||||||
DC Voltmeter (Moving coil) |
1 V to 100 V | 1 V to 150 V | 1 V to 300 V | |||||||||||
Receiving meter (Moving coil) |
4 to 20 mA 1 to 5 V (4 kΩ) 1 to 5 V (1 MΩ, with external Converter 7331) |
4 to 20 mA 1 to 5 V (4 kΩ) 1 to 5 V (1 MΩ) |
||||||||||||
AC Ammeter | Rectifier type | - | 1 mA | 1 mA to 300 mA | 1 mA | |||||||||
RMS effective value type | 1 A to 30 A (with external Converter 7311) | 1 A to 5 A (built-in CT) 10 A to 30 A (with Converter 7311) |
||||||||||||
AC Voltmeter | 10 V to 300 V (with Multiplier) |
10 V to 150 V | 10 V to 300 V |
◎Twice or three times extended scale can be manufactured if the rated current of AC Ammeter is more than 1 A.
◎When the rated value is exceeded in DC Ammeter, connect the shunt and analog meter with 60 mV rated value (except T□E-152).
◎When the rated valueis exceeded in DC voltmeter, connect the multiplier and analog meter with 1 mA rated voltage.
◎When the rated value is exceeded in AC Ammeter, connect the current transformer (CT) with analog meter with 5 A rated current.
◎When the rated value is exceeded in AC voltmeter, connect voltage transformer (VT) and analog meter with 100 V rated voltage.
Customers are requested to provide the following information during order.
- 1. Model
- 2. Rated input value
- 3. Scale and Unit
- 4. Vertical or Horizontal installation
※Receiving meter of DC 1 to 5 V (1 MΩ)needs power supply.