AC mΩ Meter

MODEL 356M AC mΩ tester with 20 CH Scanner

  • ■AC mΩ meter, max. 40 CH scanner possible
  • ■Resistance measurement range 30 mΩ/300 mΩ/3 Ω
  • ■Open terminal voltage 20 mV peak or less
  • ■Enables to measure cell voltage and resistance of rechargeable battery and Fuel cell.
  • ■2 outputs of upper comparison judgment

Catalog
Operation manual

Typical Application

Internal resistance of Battery, contact resistance etc.

Model Designation

Main unit
356M-□
Model The number of CH  
356M-05 5CH Extension unit NOT available
356M-10 10CH
356M-15 15CH
356M-20 20CH Extension unit available
Scanner extension unit
5811-71-□
Model CH number of extension
5811-71-05 5CH
5811-71-10 10CH
5811-71-15 15CH
5811-71-20 20CH

Standard Specifications

Measuement range

■Resistance measurement
Measurement range Note 1 30 mΩ 300 mΩ 3 Ω
Resolution 1 μΩ 10 μΩ 100 μΩ
Measuring current 7.4 mA 1 mA 100 μA
Accuracy Note 2 ± (0.5 % of rdg. + 8 dgt.)
Temperature coefficient ± (0.05 % of rdg. + 0.8 dgt.) / ℃
Open terminal voltage Less than 20 mV peak (with OFF function)
■Voltage measurement
Measurement range Note 1 ± 5 V ± 50 V
Resolution 100 μV 1 mV
Accuracy Note 2 ± (0.05 % of rdg. + 5dgt.)
Temperature coefficient ± (0.005 % of rdg. +0.5 dgt.) / ℃

Note1: All CH, the same range
Note 2: Specified at 23 ℃ ± 5 ℃, 45 to 75 % RH


Specification

Measuring method AC 4 terminal method (Resistance measurement)
Measuring frequency AC 1 kHz ± 20 Hz (Resistance measurement)
Sampling cycle 10 times / s. (Resistance, voltage measurement)
Measurement terminal Connector of 2.54 mm pitch, MIL-C-86503 standard
Wiring resistance Source side: Less than 0.1 Ω
Display LCD display
Resistance measurement: 35000
Voltage measurement: 50000 (with polarity indication)
Measuring mode
Automatic measurement: Measure resistance and voltage from CH 1 till set CH,
then switched to waiting.
'AUTO' mode: The measured data is saved in 356M, the data can be downloaded to PC.
'FULL' mode: Each measurement of each CH is output.
Manual measurement: Resistance and voltage of manually set CH are measured.
Measuring time
(During automatic measurement)
Select 1 s. or 2 s. for one CH
Measuring time of 1 s.:aprx. 900 ms., 2 s.: aprx.1900 ms.
Judgment Upper limit (H1, H2) can be set.
Output condition: The resistance of more than 1 CH > H1・・・ Relay ON
The resistance of more than 1 CH > H2・・・ Relay ON
Contact capacity: AC 250 V, 1 A (Resistance load), 1 A. 1a contact
Insulation resistance DC 500 V, more than 50 MΩ
Withstanding voltage AC 1500 V, 1 min.
Power supply tolerance AC 90 to 250 V (356M, 5811-71)
Operating ambient temperature 0 to 50 ℃
Storage temperature -20 to 70 ℃
Weight 356M aprx. 1 kg, 5811-71 aprx. 1 kg
Dimension 205 (W) x 64 (H) x 169 (D) mm
Serial communication  RS-232C
Transmission system: Start-stop synchronization full duplex
Transmission rate: 2400, 4800, 9600 bps
Data bit length: 7 bit, 8 bit
Stop bit: 1 bit
Xon, Xoff: No Control
Accessory
356M Utility software (CD) 1 pc
RS-232C cable 1 pc
Power cord 1 pc
Power fuse 1 pc
Operation manual 1 pc
5811-71 Power cord 1 pc
Unit connect cable 1 pc
Measurement cable Not included, manufacturable based on meeting with us.