Our Technology, solution for Tomorrow too!

Digital Meter

DC Voltmeter / Ammeter, Receiver

MODEL 3124

  • ■ DIN size 48×24 mm Compact design.
  • ■ Available with full scale display -19999 to 19999 optional setting.
  • ■ Available with variable offset display function.

Operation manual

Standard Specifications

Model Designation

3124 - - -

①Measuring Input

Code Measuring Range Input Resistance Accuracy  * Overload
03 ±1.9999 V 1 MΩ ±(0.05% of rdg + 2 digit) DC ±250 V
04 ±19.999 V 1 MΩ ±(0.05% of rdg + 2 digit) DC ±250 V
05 ±199.99 V 10 MΩ ±(0.05% of rdg + 2 digit) DC ±500 V
09 DC 1 to 5 V 1 MΩ ±(0.1% of rdg + 5 digit) DC ±250 V
V1 DC 0 to 1 V 1 MΩ ±(0.05% of rdg + 2 digit) DC ±250 V
V2 DC 0 to 5 V 1 MΩ ±(0.05% of rdg + 2 digit) DC ±250 V
V3 DC 0 to 10 V 1 MΩ ±(0.05% of rdg + 2 digit) DC ±250 V
19 DC 4 to 20 mA 13 Ω ±(0.1% of rdg + 5 digit) DC ±150 m A
A1 DC 0 to 1 mA 200 Ω ±(0.1% of rdg + 2 digit) DC ±50 mA
* Accuracy:
Defined at 23℃ ± 5℃, 45 to 75% RH.
Temperature coefficient:
± 200 ppm/℃ (Temp. range 0 to 50℃)

②Display Color

Code Description
Blank Red LED
Green LED

③Option

Code Input
Blank null
A01 Display cycle 1s
A02 Fixed 100 digit to 0
A03 Display sampling 1s, Fixed 100 digit to 0

General Specifications

Display 0 - 19999 red or green LED (character height 8 mm) with zero-suppress function.
Scaling function Full scale display -19999 to +19999 (with full scale display setting function)
Offset display -19999 to +19999 (with offset display setting function)
Offset fixing function Function of fixing display value to offset value when input is less than offset value.
Decimal point Optional setting by the connector (Not isolated from input).
Over-range indication Flashing with 130% display.
(But when exceeded 19999, flashing is displayed by 0000.)
Hold function Holds measured data (Not isolated from input).
Resolution 1/20000
Display cycle Approx. 400 ms
Input configuration Single ended, floating input
A/D conversion ⊿-Σ conversion system
Noise rejection Normal mode (NMR) – More than 50dB
Insulation resistance DC 500 V More than 100 MΩ
Withstand voltage Between input terminals and external case: AC 1500 V each for 1min.
Between power supply terminals and external case: AC 1500 V each for 1min.
Between power supply terminals and input terminals: AC 500 V each for 1min.
Power supply DC 4.75 to 32 V
Power consumption Approx. 100 mA at 5 V.
Approx. 50 mA at 12 V.
Approx. 35 mA at DC 24 V
Operating temperature 0 to 50°C
Storage temperature -20 to 70°C
Weight Approx. 45 g

page top