Our Technology, solution for Tomorrow too!

Bargraph Meter

Bar Graph Meter・Meter Relay

MODEL 1961, 1963, 1964

  • ■3 types of light emission of bar graph available:
    Orange, Green, Red
  • ■Easy reading because of digital display
  • ■Indicator with 2 points setting, 4 points setting relay mete
  • ■Power available for AC as well as DC

Operation manual

Model Designation

196 - -
  A   B   C
A Setting Points
Code Settings
1 Without setting
3 2 set points
4 4 set points
B Input
Code Input
1 DC 0-1 mA
2 DC 4-20 mA
3 DC 0-1 V
4 DC 1-5 V
5 DC 0-5 V
0 Other than those above *1
*1:
Input Voltage less than DC 10 V
Input Current less than DC 50 mA
C Power Supply
Code Power Voltage
A AC 85-264 V
7 DC 5 V *2
9 DC 24 V
*2:
Terminals between power supply and input are non-isolated.

Specifications

  1961 1963 1964
Bar Graph Display
Display colors Red, Green, Orange(3 colors display)
Display elements Red & Green
Bar dots 101
Scale length 100 mm (1.5 mm width)
Accuracy ±(1% of FS + 1 digit)
Response time 0.5s
Scale plate Black Aluminum(White scale & white characters)
Digital Display
Display colors 0-9999 LED (Color: Red)(8×4 mm)
Scaling full scale・・・-1999 to 9999 off set value・・・-1999 to 9999 Scaling is not available which inversely proportional to input value.
Resolution 1/2000
Sampling period 12 times/sec.
Accuracy ±(0.5% of FS + 1 digit)
Range of move averaged sampling select from 1, 2, 4, 8 or 16 times step
ON delay 0 - 15sec.(1sec interval)
Setting range No Relay Output H :(set value of L + 1%)to 100%
L :(set value of H - 1%)to 0%
HH :(set value of H + 1%)to 100%
H :(set value of HH - 1%)to(set value of L + 1%)
L :(set value of H - 1%)to(set value of LL + 1%)
LL :(set value of L - 1%)to 0%
Relay output H : 1 transfer
L : 1 transfer
H / L : Each contact 1a
HH / LL : 1 transfer *
Hysteresis 1% of FS
Contact capacity AC 125 V, 0.5 A
Insulation resistance Between all terminals and outer case DC500V More than 10MΩ
Withstanding voltage
Between input terminals and outer case AC 1500 V 1min.
Between input and Power Supply terminals AC 1500 V 1min.(AC)
Between input and Power Supply terminals AC 500 V 1min.(DC 24 V)
Between Relay contacts and Other Circuits AC 1000 V 1min.
Power supply AC 85-264 V 50/60 Hz
DC 24 V ± 15%
DC 5 V ± 5%
Power consumption 7 VA(AC 85-264 V)
6 W(DC 24 V)
3 W(DC 5 V)
Operating temperature 0 to 45°C
Storage temperature -20 to 70°C
Weight Applox. 400 g Applox. 420 g

*2 HH and H : Common terminal are common, LL and L : Common terminals are common

Input Specifications

Code Input Signal Input Impedance
1 DC 0-1 mA 200 Ω
2 DC 4-20 mA 10 Ω
3 DC 0-1 V 1 MΩ
4 DC 1-5 V
5 DC 0-5 V

Colors of Bar Display

●1961・1963

Colors of Bar Display 1961・1963

●1964

Colors of Bar Display 1964

●Option Display

Colors of Bar Display Option Display
When the input value is less than setting value, it indicates orange color of bar. When the input value exceeds less than the setting value, it indicates the green color bar. When the input value exceeds more than the setting value, it changes to red color bar
No. 1 2 3 4 5 6 7 8 9 10 11 12
Max. value 1 1.2 1.5 2 2.5 3 4 5 6 7.5 8 9
Division No. 50 24 30 40 50 30 40 50 30 37.5 40 45

page top