Our Technology, solution for Tomorrow too!

Bargraph Meter

Bargraph Meter

MODEL 1931

  • ■Digital indicator on bar graph display
  • ■Digital indicator with scaling function
  • ■Clear bar graph display with custom LED Adoption.

Operation manual

Model Designation

1931 - -
  B   C
B Input
Code Input
1 DC 0-1 mA
2 DC 4-20 mA
3 DC 0-1 V
4 DC 1-5 V
5 DC 0-5 V
0 Other than those above *1
*1:
Input Voltage Less than DC 10 V
Input Current Less than DC 50 mA
C Power Supply
Code Power Voltage
A AC 85-264 V
7 DC 5 V *2
9 DC 24 V
*2:
Terminals between power supply and input are non-insulated.

Specifications

Bar Graph Display Display LED (Color: Red)
Bar dots 101
Scale length 100 mm (1.5 mm width)
Accuracy ±(1% of FS + 1 digit)
Response time 0.5s
Scale plate Black Aluminum(White scale & characters)
Digital Display Display 0-9999 LED (Color: Red) (8×4 mm)
Scaling full scale・・・-1999 - 9999 off set value・・・-1999 - 9999 * not available for reverse proportion to input value.
Resolution 1/2000
Sampling period 12 times/sec.
Accuracy ± (0.5% of FS + 1 digit)
Insulation resistance All terminals - Case  DC 500 V, More than 10 MΩ
Withstanding voltage
Between all terminals and outer case AC 1500 V 1min.
Between power Supply and input terminals AC 1500 V 1min.(AC)
Between power Supply and Input terminals AC 500 V 1min.(DC 24 V)
Power supply AC 85-264 V 50/60 Hz
DC 24 V ± 15%
DC 5 V ± 5%
Power consumption 7 VA(AC 85-264 V)
4 W(DC 24 V)
2 W(DC 5 V)
Operating temperature 0 to 45°C
Storage temperature -20 to 70°C
Weight Applox. 420 g

Input Specifications

Code Input Signal Input Impedance
1 DC 0-1 mA 200 Ω
2 DC 4-20 mA 10 Ω
3 DC 0-1 V 1 MΩ
4 DC 1-5 V
5 DC 0-5 V
No. 1 2 3 4 5 6 7 8 9 10 11 12
Max. value 1 1.2 1.5 2 2.5 3 4 5 6 7.5 8 9
Division No. 50 24 30 40 50 30 40 50 30 37.5 40 45